{"id":8446,"date":"2026-04-13T15:15:28","date_gmt":"2026-04-13T13:15:28","guid":{"rendered":"https:\/\/www.def-france.fr\/actualites\/apsad-r7-additif-2025-en\/"},"modified":"2026-09-15T11:36:07","modified_gmt":"2026-09-15T09:36:07","slug":"apsad-r7-additif-2025","status":"publish","type":"business-news","link":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/actualites\/apsad-r7-additif-2025\/","title":{"rendered":"APSAD R7: the 2025 Amendment officially incorporates linear heat detection"},"content":{"rendered":"<section class=\"custom-block text-button-block\">\n    <div class=\"container\">\n        <div class=\"text-with-button !bg-white my-4\">\n            \n            <h2 id=\"apsad-r7-what-changes-with-the-september-2025-amendment\" class=\"joli-heading jtoc-heading\">APSAD R7: what changes with the September 2025 Amendment<\/h2>\n<p>L\u2019additif APSAD R7 publi\u00e9 en septembre 2025 vient <strong>compl\u00e9ter et consolider<\/strong> The APSAD R7 Amendment, published in September 2025, supplements and reinforces the existing recommendations in the standard. It does not call into question the overall structure of the rule, but provides crucial technical clarifications, particularly regarding: <strong>pr\u00e9cisions techniques d\u00e9terminantes<\/strong><\/p>\n<ul>\n<li>the expansion of established detection technologies,<\/li>\n<li>the terms of use for certain devices,<\/li>\n<li>the integration of new power supply architectures,<\/li>\n<li>and limiting practices that could hinder early detection.<\/li>\n<\/ul>\n<p>This change is part of an effort to better adapt to complex environments\u2014whether industrial or technical\u2014while maintaining the high standards of reliability expected by insurers. <strong><\/strong>, <strong>industriels<\/strong> ou <strong>techniques<\/strong><\/p>\n<h2 id=\"linear-heat-detection-officially-integrated-into-apsad-r7\" class=\"joli-heading jtoc-heading\">Linear heat detection: officially integrated into APSAD R7<\/h2>\n<p><strong>A major breakthrough in fire detection<\/strong><\/p>\n<p>La <strong>d\u00e9tection lin\u00e9aire de chaleur (DLC)<\/strong> Linear heat detection (LHD) is now an integral part of the APSAD R7 Standard. It is supported by a comprehensive framework for design, installation, validation, and maintenance, which is formalised in a new dedicated section: <strong>cadre complet de conception, d\u2019installation, de validation et de maintenance<\/strong><strong>\u00a7 2.6.2.13<\/strong>. This integration marks a key milestone: until now, the LHD was recognised through European standards, but there was no detailed French framework for its operational deployment. <strong>sans r\u00e9f\u00e9rentiel fran\u00e7ais d\u00e9taill\u00e9<\/strong><\/p>\n<h2 id=\"resettable-and-non-resettable-detectors-a-clarified-regulatory-framework\" class=\"joli-heading jtoc-heading\">Resettable and non-resettable detectors: a clarified regulatory framework<\/h2>\n<p>The amendment clearly distinguishes between two main families of linear heat detectors:<\/p>\n<ul>\n<li><strong>D\u00e9tecteurs r\u00e9enclenchables<\/strong>Resettable detectors, compliant with the NF EN 54-22 Standard, Non-resettable detectors, compliant with the NF EN 54-28 Standard. Whether they are multi-point or distributed, these systems are now subject to specific requirements regarding: <strong>norme NF EN 54-22<\/strong>,<\/li>\n<li><strong>D\u00e9tecteurs non r\u00e9enclenchables<\/strong><strong>norme NF EN 54-28<\/strong>.<\/li>\n<\/ul>\n<p>Qu\u2019ils soient <strong>multiponctuels ou distribu\u00e9s<\/strong><\/p>\n<ul>\n<li>their establishment,<\/li>\n<li>their configuration,<\/li>\n<li>their validation criteria,<\/li>\n<li>their integration into the fire detection system.<\/li>\n<\/ul>\n<p>This clarification makes the work of engineering firms, installers, and operators easier, while ensuring that installations comply with APSAD requirements.<\/p>\n<h2 id=\"complex-environments-are-now-fully-covered\" class=\"joli-heading jtoc-heading\">Complex environments are now fully covered<\/h2>\n<p>Linear heat detection is particularly well-suited for environments where point detection reaches its limits <strong><\/strong>.<br>\nThe APSAD R7 Amendment explicitly recognises these use cases, including:<\/p>\n<ul>\n<li><strong>tunnels et infrastructures souterraines<\/strong>,<\/li>\n<li><strong>galeries de c\u00e2bles<\/strong>,<\/li>\n<li><strong>convoyeurs industriels<\/strong>,<\/li>\n<li><strong>machines et \u00e9quipements \u00e0 g\u00e9om\u00e9trie complexe<\/strong>,<\/li>\n<li><strong>zones \u00e0 atmosph\u00e8res difficiles<\/strong> (poussi\u00e8res, hauteurs importantes, contraintes thermiques).<\/li>\n<\/ul>\n<p>tunnels and underground infrastructure, cable trays, industrial conveyors, machines and equipment with complex geometries, areas with harsh environmental conditions (dust, great heights, extreme temperatures). For these configurations, the LHD is the go-to solution, providing reliable, continuous detection over long distances or large areas. <strong>solution de r\u00e9f\u00e9rence<\/strong><\/p>\n<h2 id=\"standard-households-use-now-strictly-regulated\" class=\"joli-heading jtoc-heading\">Standard households: use now strictly regulated<\/h2>\n<p>Another important clarification provided by the amendment:<br>\nles <strong>foyers types de site<\/strong> Another important clarification provided by the amendment: site-specific households can no longer be used to compensate for a detection shortfall. They are now strictly reserved for situations where: <strong>compenser un d\u00e9ficit de d\u00e9tection<\/strong><strong>strictement r\u00e9serv\u00e9s<\/strong><\/p>\n<ul>\n<li>it is technically impossible to position the detectors,<\/li>\n<li>or the layout of the premises does not allow for installation in compliance with regulations.<\/li>\n<\/ul>\n<p>This restriction is intended to preserve the speed and early detection that are fundamental principles of the APSAD R7 rule, and to prevent any design deviations. <strong><\/strong><\/p>\n<h2 id=\"detection-methods-building-on-the-principles-introduced-in-2021\" class=\"joli-heading jtoc-heading\">Detection methods: building on the principles introduced in 2021<\/h2>\n<p>Les <strong>modes de d\u00e9tection<\/strong>The detection modes\u2014which were expanded in the 2021 update to increase the variety of combinations used in fire alarm confirmation\u2014are reviewed and consolidated. Amendment 2025 explicitly incorporates linear heat detection into these confirmation procedures, thereby strengthening the overall consistency of detection and safety scenarios. <strong>confirmation d\u2019alarme feu<\/strong><strong>d\u00e9tection lin\u00e9aire de chaleur<\/strong><\/p>\n<h2 id=\"power-supply-integration-of-poe-equipment\" class=\"joli-heading jtoc-heading\">Power supply: integration of PoE equipment<\/h2>\n<p>The APSAD R7 Amendment also includes a provision regarding power supply equipment that incorporates PoE, PoE+, and PoE++ switches. This equipment is now taken into account for powering certain detection devices, in particular image-analysis detectors, as described in Annex 13 of the standard. This change goes hand in hand with the growing use of IP architectures in fire safety systems, while maintaining high standards for availability and reliability. <strong>\u00e9quipements d\u2019alimentation \u00e9lectrique (EAE)<\/strong><strong>switchs PoE, PoE+ et PoE++<\/strong><strong><\/strong>, d\u00e9crits \u00e0 l\u2019<strong>annexe 13<\/strong><strong>architectures IP<\/strong><\/p>\n<h2 id=\"operational-scope-of-the-apsad-r7-amendment-for-operators\" class=\"joli-heading jtoc-heading\">Operational scope of the APSAD R7 Amendment for operators<\/h2>\n<p>With this amendment, the APSAD R7 Standard provides a clearer technical framework for technologies and use cases that were previously covered only minimally or not at all explicitly in the text, particularly linear heat detection.<\/p>\n<p>This development makes it possible, in particular, to:<\/p>\n<ul>\n<li>formalise the conditions for using linear heat detection for ambient or object detection;<\/li>\n<li>specify the rules governing the establishment, design, and implementation of these systems;<\/li>\n<li>minimise differing interpretations during the design, installation, and verification phases;<\/li>\n<li>ensure the technical reliability of detection systems in complex environments (tunnels, cable ducts, machinery, conveyors).<\/li>\n<\/ul>\n<p>For facility operators and safety managers, this amendment serves primarily as a tool for clarifying regulatory requirements, facilitating the design and operation of fire detection systems that comply with the APSAD R7 Standard.<\/p>\n\n\n            \n                    <\/div>\n    <\/div>\n<\/section>\n\n\n<section class=\"custom-block business-news-synthesis-block\">\n  <div class=\"container\">\n    <div class=\"title\">APSAD R7 2025: key points to remember<\/div>\n\n    \n          <ul class=\"briefs\">\n                  <li>Linear Heat Detection (LHD) is officially included in APSAD R7, with a clear French regulatory framework.<\/li>\n                  <li>The framework is evolving with more precise rules, limiting abuses and enhancing the reliability of the systems.<\/li>\n                  <li>LHD detectors are now clearly classified according to their type and mode of operation.<\/li>\n                  <li>Complex environments are finally better addressed, with validated, tailored solutions.<\/li>\n                  <li>Standard screening programs can no longer compensate for a lack of detection, underscoring the need for early detection.<\/li>\n                  <li>Modern (PoE) architectures are integrated, supporting the transition of systems to IP.<\/li>\n              <\/ul>\n      <\/div>\n<\/section>\n\n\n  \r\n<style>\r\n  .wpj-jtoc.--jtoc-theme-basic-light.--jtoc-has-custom-styles {\r\n      --jtoc-numeration-suffix: \". \";    }<\/style>\r\n\r\n<div id=\"wpj-jtoc\" class=\"wpj-jtoc wpj-jtoc--main --jtoc-the-content --jtoc-theme-basic-light --jtoc-title-align-left --jtoc-toggle-icon --jtoc-toggle-position-right --jtoc-toggle-1 --jtoc-has-numeration --jtoc-has-custom-styles --jtoc-is-unfolded\" >\r\n  <!-- TOC -->\r\n  <div class=\"wpj-jtoc--toc \" >\r\n              <div class=\"wpj-jtoc--header\">\r\n        <div class=\"wpj-jtoc--header-main\">\r\n                    <div class=\"wpj-jtoc--title\">\r\n                        <span class=\"wpj-jtoc--title-label\">Sommaire<\/span>\r\n          <\/div>\r\n                                <div class=\"wpj-jtoc--toggle-wrap\">\r\n                                                          <div class=\"wpj-jtoc--toggle-box\">\r\n                  <div class=\"wpj-jtoc--toggle\"><\/div>\r\n                <\/div>\r\n                          <\/div>\r\n                  <\/div>\r\n      <\/div>\r\n            <div class=\"wpj-jtoc--body\">\r\n            <nav class=\"wpj-jtoc--nav\">\r\n        <ol class=\"wpj-jtoc--items\"><li class=\"wpj-jtoc--item --jtoc-h2\">\r\n        <div class=\"wpj-jtoc--item-content\" data-depth=\"2\">\r\n                        <a href=\"#apsad-r7-what-changes-with-the-september-2025-amendment\" title=\"APSAD R7: what changes with the September 2025 Amendment\" data-numeration=\"1\" >APSAD R7: what changes with the September 2025 Amendment<\/a>\r\n                    <\/div><\/li><li class=\"wpj-jtoc--item --jtoc-h2\">\r\n        <div class=\"wpj-jtoc--item-content\" data-depth=\"2\">\r\n                        <a href=\"#linear-heat-detection-officially-integrated-into-apsad-r7\" title=\"Linear heat detection: officially integrated into APSAD R7\" data-numeration=\"2\" >Linear heat detection: officially integrated into APSAD R7<\/a>\r\n                    <\/div><\/li><li class=\"wpj-jtoc--item --jtoc-h2\">\r\n        <div class=\"wpj-jtoc--item-content\" data-depth=\"2\">\r\n                        <a href=\"#resettable-and-non-resettable-detectors-a-clarified-regulatory-framework\" title=\"Resettable and non-resettable detectors: a clarified regulatory framework\" data-numeration=\"3\" >Resettable and non-resettable detectors: a clarified regulatory framework<\/a>\r\n                    <\/div><\/li><li class=\"wpj-jtoc--item --jtoc-h2\">\r\n        <div class=\"wpj-jtoc--item-content\" data-depth=\"2\">\r\n                        <a href=\"#complex-environments-are-now-fully-covered\" title=\"Complex environments are now fully covered\" data-numeration=\"4\" >Complex environments are now fully covered<\/a>\r\n                    <\/div><\/li><li class=\"wpj-jtoc--item --jtoc-h2\">\r\n        <div class=\"wpj-jtoc--item-content\" data-depth=\"2\">\r\n                        <a href=\"#standard-households-use-now-strictly-regulated\" title=\"Standard households: use now strictly regulated\" data-numeration=\"5\" >Standard households: use now strictly regulated<\/a>\r\n                    <\/div><\/li><li class=\"wpj-jtoc--item --jtoc-h2\">\r\n        <div class=\"wpj-jtoc--item-content\" data-depth=\"2\">\r\n                        <a href=\"#detection-methods-building-on-the-principles-introduced-in-2021\" title=\"Detection methods: building on the principles introduced in 2021\" data-numeration=\"6\" >Detection methods: building on the principles introduced in 2021<\/a>\r\n                    <\/div><\/li><li class=\"wpj-jtoc--item --jtoc-h2\">\r\n        <div class=\"wpj-jtoc--item-content\" data-depth=\"2\">\r\n                        <a href=\"#power-supply-integration-of-poe-equipment\" title=\"Power supply: integration of PoE equipment\" data-numeration=\"7\" >Power supply: integration of PoE equipment<\/a>\r\n                    <\/div><\/li><li class=\"wpj-jtoc--item --jtoc-h2\">\r\n        <div class=\"wpj-jtoc--item-content\" data-depth=\"2\">\r\n                        <a href=\"#operational-scope-of-the-apsad-r7-amendment-for-operators\" title=\"Operational scope of the APSAD R7 Amendment for operators\" data-numeration=\"8\" >Operational scope of the APSAD R7 Amendment for operators<\/a>\r\n                    <\/div><\/li><\/ol>      <\/nav>\r\n          <\/div>\r\n      <\/div>\r\n<\/div>\r\n","protected":false},"excerpt":{"rendered":"<p>The APSAD R7 standard, which governs the design, installation, and maintenance of fire detection systems, has been updated with the publication of a major amendment in September 2025.<br \/>\nThis update enhances the reliability of detection systems by incorporating new technical requirements and clarifying certain key points for operators, specifiers, and insurers.<\/p>\n","protected":false},"featured_media":2101,"template":"","product_taxonomy":[],"profession":[],"sector":[],"service":[],"solution":[],"business_news_category":[],"class_list":["post-8446","business-news","type-business-news","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/business-news\/8446","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/business-news"}],"about":[{"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/types\/business-news"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/media\/2101"}],"wp:attachment":[{"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/media?parent=8446"}],"wp:term":[{"taxonomy":"product_taxonomy","embeddable":true,"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/product_taxonomy?post=8446"},{"taxonomy":"profession","embeddable":true,"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/profession?post=8446"},{"taxonomy":"sector","embeddable":true,"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/sector?post=8446"},{"taxonomy":"service","embeddable":true,"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/service?post=8446"},{"taxonomy":"solution","embeddable":true,"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/solution?post=8446"},{"taxonomy":"business_news_category","embeddable":true,"href":"https:\/\/def-tunisie-preprod.wp-ylly.hunik.tech\/en\/wp-json\/wp\/v2\/business_news_category?post=8446"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}